Shipping Address: Moldlab, Ltd 3245 Main St. Suite # 235 Frisco TX 75034 972-247-9373
For hand delivered samples, call for instructions
|
Sample Overview
(a) Bulk and Swab samples can be tape-lifted for direct examination(b) Quantification of cultured Bulk sample requires that more than 1 gram of sample be provided(c) Quantification of cultured Swab sample requires that the area sampled (9 cm2, 1 square inch, etc...) be measured and provided(d) Not for true quantification, but a semi-quantitative rating is provided (trace, minor, major, abundant)
General: Non-cultured samples involve direct exam and identification of individual spores. Some mold types such as Aspergillus and Penicillium are not distinguishable by their spores alone, so for non-cultured samples some molds have to be grouped together like Aspergillus\Penicillium. Direct exams do not require any growing time, so rush or same day results are available at additional cost. Cultured samples are grown in a petri dish for several days before analysis, and the entire colony, not just the spore, is utilized for the identification. This enables better or more exacting identification of certain mold types, but certain molds don’t grow at all in standard culture media or will grow very slowly. Additionally, dead spores will not grow at all even though these spores can have the same health effects as viable spores. Rush results are not available because cultures require a certain amount of time to grow (7-10 days, which can vary from sample to sample.) Stachybotrys in particular does not grow well in standard culture media, and direct examination is the preferred method of identification (airocell/allergenco or tape). If you are specifically testing for Stachybotrys using a cultured method, then other media types such as Rose Bengal might be preferred or requested instead of Malt Extract Agar. Gravity plates (commonly found in "home test kits") are not generally used by professionals
Air-o-cell and Allergenco samples require specialized equipment. This type of sample is a non-cultured air sample. Results are reported in concentrations of spores per cubic meter (spores/m3). This test is referred to as a "snapshot" of the air at the exact time of sampling. Results account for both alive and dead spores as well as pollen, skin, insect parts etc. (if a full profile analysis is requested). It is important to note that allergic reactions can come from dead spores and alive spores alike. In addition, the toxins that some fungal spores produce remain toxic after the spore itself has died. Air-o-cells can also be used to test inside a wall cavity (by removing a light switch panel or other opening. Usually only 15 to 30 liters is the most one can sample before completely overloading the sample with drywall dust.) Normal laboratory turnaround time is usually several days, but rush or same day results are available for additional cost. Interpretation of Results The general guideline to follow is that the concentration and types of spores in the inside sample should be similar to or lower than the concentration and types of spores found in the out of doors sample. Do to the high variability in results, this test is mainly useful as a "check" to alert one to potential problems that might have been missed by visual inspection. Accurate measurements of true airborne concentrations requires multiple samples taken during different times, and it can involve complex statistical analysis. The category Aspergillus / Penicillium are small (1-3 microns), round, colorless spores that may include: Gliocladium, Trichoderma, other morphologically consistent with Aspergillus / Penicillium types. A culture sample would be necessary to differentiate between them. Currently there are no dose response relationship statistics for allowable or safe levels of aeroallergens. However if spores of Aspergillus / Penicillium are found at higher levels than outside, or Stachybotrys are found inside at even low concentrations, further investigation of the source should be conducted and evaluated by a professional. For information about types of molds found on the lab report, please see glossary page. How to sample
Air-o-cell Sampling Procedure:
Allergenco Sampling Procedure: please refer to owner’s manual supplied by the manufacturer ANDERSEN SAMPLES Andersen samples require specialized equipment. This type of sample is a cultured air sample grown in the laboratory on Malt Extract Agar or other media. Results are reported in concentrations of CFU’s per cubic meter (CFU/m3). Results indicate the number of viable (alive) spores in the air at the time of sampling. Cultured samples such as this allow better differentiation of certain mold types such as Aspergillus and Penicillium because once growth occurs, you are identifying colonies rather than just individual spores. On the other hand, certain molds do not grow or compete well on standard culture media. Analysis does not and cannot include counts for dead spores, pollen, skin, insect parts, etc. It is important to note that allergic reactions can come from dead spores as well as live spores. In addition, the toxins that some fungal spores produce remain toxic after the spore itself has died. Normal laboratory turnaround time is 7 to 10 days (cultures require time to grow and it is impossible to provide rush service.) Interpretation of Results The general guideline to follow is that the concentration and types of colonies found in the inside sample should be similar to or lower than the concentration and types of colonies found in the out of doors sample. Do to the high variability in results, this test is mainly useful as a "check" to alert one to potential problems that might have been missed by visual inspection. Accurate measurements of true airborne concentrations requires multiple samples taken during different times, and it can involve complex statistical analysis. Currently there are no dose response relationship statistics for allowable or safe levels of aeroallergens. Please note that Stachybotrys does not grow well on most laboratory media and an absence of Stachybotrys on a culturable sample report should not rule out this type of mold. For information about types of molds found on lab report, please see glossary page. How to sample
Andersen Sampling Procedure: please refer to owner’s manual supplied by the manufacturer
Bulk samples are a little trickier to take than swabs or tape-lifts, and these are more appropriate for certain kinds of materials where the spores might be present beneath the surface (such as thermal insulation.) These are usually analyzed by culturing, though the surface can also be tape-lifted (see below) for direct exam. The cultured sample is grown in the laboratory on Malt Extract Agar or other media. Results are reported in concentrations of colony forming units per gram of sample (CFU/g). The results of a bulk sample culture can be problematic because of the inconsistency of contamination of the material sampled. Additionally, Stachybotrys does not grow well on standard culture media, and an absence of Stachybotrys on a culturable sample report should not rule out this type of mold. Normal laboratory turnaround time is 7-10 days for culture and/or several days for direct exam. Rush or same day results at additional charge are available for direct exams, but cultures require time to grow and it is impossible to provide rush service for these. Interpretation of Results less than 10,000 is low 10,000 to 100,000 is medium 100,000 to 1,000,000 is medium to heavy greater than 1,000,000 is heavy For information about types of molds found on lab report, please see glossary page. How to Sample
Bulk Sample Procedure:
Swab samples are easier to take, however, you must have a sterile swab for testing (these are available from Moldlab for a nominal fee). This type of sample can be cultured and\or analyzed directly. For the cultured swab, results are reported in colony forming units per square inch of material. For direct exam swab samples, results are reported semi-quantitatively like tape-lifts (trace, minor, major, abundant). Swab samples are a good choice if the suspect area is hard to access, or if you wish to do a direct exam and a culture from the same spot. Be aware that large surfaces can have multiple mold types spanning across it, and a single one square inch swab might not be inclusive or representative of all the molds. Normal laboratory turnaround time is 7-10 days for cultures and/or several days for direct exam. Rush or same day results at additional charge are available for direct exams, but cultures require time to grow and it is impossible to provide rush service for these. Interpretation of Results Cultured swab samples are used if both concentration and type of mold data is needed. For information about types of molds found on lab report, please see the glossary page. How to Sample
Swab Procedure:
Tape samples are the quickest and easiest method of testing. No special equipment is needed for this non-cultured sample. Results are reported semi-quantitatively as a rating (trace, minor, major, abundant) so that one can have an idea of relative amounts if more than one mold is present, though this test is primarily used qualitatively to identify visible mold or to check surfaces for trace amounts of Stachybotrys. If results are negative, a bulk or swab culture of the material might be recommended to verify results because spores can be down inside the material and can be missed by direct exam. Also, be aware that large surfaces can have multiple mold types spanning across it, and a single square half-inch tape-lift might not be inclusive or representative of all the molds. Most people use this test in combination with an quantitative analysis such as Andersen or Air-o-cell / Allergenco. Normal laboratory turnaround time is several days, though rush and same day results are available for additional cost.Interpretation of Results To be used to identify the type of mold to a Genus level in most cases. Not generally used for quantitative analysis, though each mold type present is rated in terms of trace, minor, major, or abundant amounts. For information about types of molds found on lab report, please see glossary page. How to Sample
Tape Lift Procedure: